Software Pricing
1. Basic Package: BBAS.ID and BBAS.Convert
Price: $4,000
A. Basic Version of BBAS.ID
-
Reads and displays data files in our openly documented digitized data file format
(the WDS format)
-
Supports marking and editing of miscellaneous points of interest in a channel of data
-
Supports detection and editing of Blink events in EOG data
Data derived from the blinks includes Closing Duration,
Blink Amplitude, and Closure Duration.
-
Supports detection and editing of Amplitude Change, Stimulus, and Response events
(represented as square wave amplitude changes)
-
Detection of supported event types is user customizable by altering detection criteria.
B. BBAS.Convert
-
Digitized Data File Conversion Utility
-
Reads digitized data files in the following formats:
-
AcqKnowledge
format (version 3.8.1) for PC's with Windows from BIOPAC Systems, Inc.
-
CODAS Data Storage Format
from Dataq Instruments, Inc.
-
ColumnarText: Textual (ASCII) data in A/D Converter Units formatted with
one column per channel of data. Supports Comma Separated Values (CSV) text files
-
ReverseColumnarText: Textual (ASCII) data in A/D Converter Units formatted
to conserve file space by leaving out missing data points on some channels.
Please contact us if you need further information about this text file format.
-
Our openly documented digitized data file format
(the WDS format)
-
Outputs files in the following formats:
-
WDS format
-
Columnar Text format
-
Floating Point CSV format
-
Allows interactive selection of channels from the input data file to be
included in the output file
-
Allows interactive selection of the time period within the original input
data file that will be included in the output file
-
Allows "re-sampling" of the data at a different sampling interval than the
input data file.
If any time point to be re-sampled does not correspond to
a sampled time point in the input data file, the user can select whether the value
to be placed in the output file for the re-sample time point is to be determined using
-
linear interpolation: in which the value output for the re-sample
time is computed using a linear interpolation between the samples in the
input file that surround the re-sample time
-
sample and hold or stair step sampling in which the value output for
the re-sample time is the most recent actual sample that is in
the input file
-
If Floating Point CSV format is chosen for the output file format, then the user
can specify a linear transformation to be performed on the data before writing the
output file. This allows the user to convert the data from the A/D units in which
it is stored in the digitized data file to "Engineering" units like
Voltages, Millimeters, Degrees, etc. provided that the user knows the correct
transformation coefficients. Some standard transformation coefficients for converting
A/D units to Voltages are preprogrammed into the software.
2. Standard Package: BBAS.ID, BBAS.Convert, and Consulting
Price: $6,000
A. Standard Version of BBAS.ID
Same functionality as the Basic Version of BBAS.ID described above, plus the following:
-
Supports User Specified Find and Delete
Ask the software to Find or Delete events on a user specified set of channels
for a user specified period within a digitized data file
-
Supports Partial Event Editing
Allows limited editing of events when viewing the data at a different sampling
interval than the actual sampling interval in the data file.
-
Supports marking and editing of user specified text (Annotations) associated with
individual points within a channel
B. BBAS.Convert
Same functionality as BBAS.Convert in the Basic Package described above.
C. Consulting
Purchase of the Standard Package includes 5 hours of consultation within 6 months of the
original purchase date to help the user:
- understand and use the software
- understand and use the algorithms for detecting events
- learn how to edit events, and
- understand how the events can be further processed for statistical analysis
and summarization
Further consulting is available at $150 per hour
3. Add-on Event Detection Algorithms
Add-on Event Detection Algorithms can be purchased after purchasing the
Standard Package. These algorithms are available for
$1,000 each. This purchase price includes 3 hours of consultation within 6 months
of the purchase of the add-on to help the user understand and use the algorithm.
Additional such consultation is available for $150 per hour.
The following Add-on Event Detection Algorithms are available:
- Saccade Detection and Editing in channels of EOG and Camera-based data
- R-wave Peak Detection and Editing in channels of ECG/EKG data
- Dropout Detection and Editing
- Saccade Style Event (SSE) Detection and Editing
This is a flexible event detection algorithm that can be used to
detect a relatively large number of different types of events. However,
to enable this level of flexibility, there are a large number of
criteria to understand and configure.
In camera-based data, this algorithm has been used successfully to identify
pupil diameter changes and minor head movements
in addition to saccadic eye movements.
4. Custom Event Detection Algorithms
New Event Detection Algorithms can be created and incorporated into BBAS.ID to
detect events of your interest. Pricing for this custom software development will
depend upon the complexity of the necessary algorithm for detecting your events
of interest. Please contact tbb(at)BioBehaviorAnalysis.com for further
information.
|